Hitachi TV, 57UWX20B
Reason for Service: Shuts down.
Solution: Horz output voltage and B+ okay; Horz output transistor collector has distorted waveform.  Replace TH01.

JVC TV, LT32DM20
Reason for Service: Set starts with OSD showing input, then shuts down.
Solution: One of the inverter transformers was bad; replacing it fixed the set. Found it by comparing to other transformers.

Panasonic TV, TH-50PZ80U
Reason for Service:  No picture or OSD after powering on; power light lit.
Solution:  Replacing A board fixed set.

Samsung TV, HLP5085WX/XAA
Reason for Service: Set makes squealing noise when powering on.
Solution: Replaced C540, 1uF/50V SM cap on DMD module.

Samsung TV,  LN-T3753HN
Reason for Service: At turn on, backlight flashes for short time, then no more backlight.
Solution: Replaced inverter.

Sony TV, KDL46W5150
Reason for Service: Set comes on for 10 seconds, then shuts down. Does this three times then gives 10 blink error code.
Solution: Try factory reset.  Turn power on, then immediately press and hold arrow up and press and release power button.

Vizio TV,  VP322HDTV10A
Reason for Service: No audio.
Solution: Replacing SM Q15 fixed problem.

Westinghouse TV, LD-3255VX
Reason for Service: Dead set.
Solution: Replacing U13/14 eeprom fixed set. TW61301-K032A69